Date on Master's Thesis/Doctoral Dissertation
5-2010
Document Type
Master's Thesis
Degree Name
M.S.
Department
Oral Biology
Committee Chair
Farman, Allan G.
Author's Keywords
Dental implant; CBCT; Cone beam; Radiographic marker; Projection
Subject
Dental implants; Diagnostic imaging; Teeth--Radiography
Abstract
Potential dental implant site assessment is initially determined clinically. Subsequent radiographic assessment also provides information about the quantity of available bone. It was hypothesized that the use of radiographic markers in mandibular stents to project the clinically derived placement of implant fixtures would not correspond to the optimal trajectory of the fixture based on acceptable implant placement criteria applied on Cone Beam Computed Tomography images. A retrospective audit of patients with edentulous mandibles scanned with a surgical guide was completed. A total of 218 potential implant sites in 77 patients were evaluated utilizing an implant planning software package (EZ Guide V1.3; Aspen Dental, Burlington, MA). Projections were found to deviate from optimal placement in more than 93% of sites. In more than 75% of such sites, the clinically projected position was buccal to optimal placement. The results suggest that clinical assessment alone is inadequate to project optimal implant fixture position.
Recommended Citation
Vaughn, William Shane 1984-, "Comparison of clinically projected and radiographically optimal implant fixture placement." (2010). Electronic Theses and Dissertations. Paper 1487.
https://doi.org/10.18297/etd/1487